FlexCase E & G
Digital Input Guide
Digital Input Specifications
| Features | Specification |
|---|---|
| Maximum Input Voltage | 36 V |
| Input HIGH level DC voltage threshold | 2.31 – 3.6 V |
| Input LOW level DC voltage threshold | 0.3 – 0.99 V |
| Default pull | Pull down |
| Pull Resistors |
49k9 down |
| Maximum Input Leakage Current | 120 nA |
| PWM Signal Frequency | 50 MHz |
| Signal Conditioning and Protection | Over Voltage, Reverse Polarity, Voltage Filtering, Current Limiting |
Digital Inputs (DI) Information
Pull up / Pull Down Configuration:
- By default all the digital inputs are pulled LOW. The Digital Input Pull-Up Enable pin (DI_Hi_Pull_EN) is used to configure the pull on the digital inputs.
- For Example, in FCE 2.1, Setting PTE14 HIGH will pull up the digital inputs 1-6. Refer datasheet for more Info.
- Each digital input is equipped with signal conditioning and protection features, including Voltage Limiting, Voltage Filtering, and Current Limiting, to safeguard the MCU.
- Make sure the input voltage is between the threshold range mentioned above for HIGH and LOW values.