FlexCase E & G
Sensor Supply Guide
Specifications
| Feature | Specification |
|---|---|
| Output Voltage | 5.0V, 12.0V, VCC |
| Output Current | 250mA* |
| Tracking | +/- 5mV |
| Dropout Voltage | 1500mV** |
| Protections | Overvoltage, Undervoltage, Short to GND, Short to Supply, Reverse Polarity, Overtemperature |
*Current level per signal output. **VCC sensor supply has near 0mV dropout.
Circuit Details
The recommended implementation for the sensor supply is as shown.

The power may need to be enabled in software. Please see the model datasheet for more information.
Alternative Configuration
For volume orders, the voltage sensor output can be configured to output 2 to 14V.